Burnum Pressure Dose Septic System


 
Alternative Pressure Dose, Leach Field
 
Alternative Pressure Dose. Efluent Transfer Lines to Leach Field
 
View more project images
Project: 
Burnum Pressure Dose Septic System Arbuckle, Colusa County
Type or Service:
Alternative Pressure Dose Septic System
Location: 
Arbuckle, CA Colusa County
Materials Used:
1.5" drain rock, schedule 40 PVC pipe and fittings, schedule 80 ball valves and gate valves, 1500 gallon concrete pump tank, effluent pump assembly and controls
Description: 
Installation of a new pressure dose leach field and concrete pump tank as a repair of a failed septic system
Scope:
* Met with the engineer, owner, and the county official to determine the size of the leach field
* Obtained the permit from the County Environmental Health Department
* Excavated the hole for the pump tank
* Installed the pump tank
* Excavated the trench for the main pressure lines to the leach field
* Installed the main pressure lines
* Excavated the trenches for the leach lines
* Installed the pressure dose leach lines
* Installed the pump assembly into the pump tank
* Installed the control panel on the house and connected the wiring to the pump assembly
* Had the septic system inspected by the county
* Installed valve boxes on all of the valves and inspection ports
* Backfilled and graded off the site
 Project Duration:
6 days

 